Boiler gas Baltgaz Neva 24 turbo. Communications to which the boiler is connected

Gas wall boilers Neva Lux (Neva Lux) Turbo 24 Turbo - double-circuit devices for heating and hot water, closed combustion chamber, electronic control, display, automatic operation, modern design, compact dimensions, wall mounting.

Gas wall-mounted boilers Neva Lux (Neva Lux) Turbo are designed for heating residential and industrial premises with an area of ​​140-240 sq.m (depending on power), and also provide full-fledged hot water supply up to 14 l / min. Boilers gas Neva Deluxe series Turbo are the latest generation of boilers from this manufacturer, equipped with a bithermic heat exchanger, European components, a closed combustion chamber, which allows you to install the boiler in ordinary rooms, for example, in the kitchen. Electronic push-button control and an information display allow you to quickly and conveniently adjust the operation of the boiler, an electronic diagnostic system helps to monitor its serviceability.
The boiler provides automatic maintenance of the set temperature with an accuracy of ± 1⁰С, is characterized by high efficiency (up to 93%), low noise level, easy maintenance. Additionally, the Neva Turbo gas boiler can be equipped with a wired control panel, a room thermostat, an outdoor temperature sensor and a GSM module for remote control boiler through the means of communication. Compact dimensions boilers Neva Lux (Neva Lux) 24 Turbo allow you to place them in a limited space, and built-in protection systems provide safety and peace of mind for users.

The warranty period is 2 years.
Country of manufacture 24 Turbo - Russia.

  • heating and hot water
  • closed combustion chamber
  • precise temperature control
  • built-in security system
  • electronic control
  • display and remote control (option)
  • wall mounting
  • compact dimensions
  • easy installation
  • affordable price

Got questions? Write, we will answer immediately!

Main characteristics

Power 24 kW

Production 14 l/min

Dimensions 700x420x270 mm

Execution vertical

Type of shell

Installation wall

Ignition type electronic

The combustion chamber closed

Weight 28.5 kg

contours 2

additional characteristics

Power 24.0 kW

Nutrition 220 V

Height 700 mm

Width 420 mm

Depth 270 mm

Weight 28.5 kg

Protection class IPX5D

Control electronic

Mounting type wall

Max. operating pressure10.0 bar

Guarantee period 2 years/years

Country of OriginRussia

Ignition type electronic

Heating area240 m2

The combustion chamber closed

Availability of the display Yes

Integrated pumpYes

Built-in boilerNot

Chimney diameter60/100 mm

Work on liquefied gasNot

Gas wall-mounted boiler BaltGaz NEVA Turbo is a new generation device. Thanks to the use of a special coating on the internal surfaces of the casing, the noise level of the boiler during operation is minimized.

BaltGaz NEVA Turbo are double-circuit wall-mounted gas boilers economy class with a separate heat exchanger and forced removal of combustion products. High efficiency for boilers of this class corresponds to the level of three stars according to the European classification. The new system of protection against the formation of condensate in the pressure switch and the pressure switch tubes increases the service life and comfort of operation. Easily removable front cover with two screws and folding side walls make maintenance as convenient as possible.

Advantages of the gas wall-mounted boiler BaltGaz NEVA Turbo

  • Double-circuit gas boiler
  • Copper heat exchanger own production for heating circuit
  • Steel plate heat exchanger for hot water circuit
  • Only European reliable components
  • AURORA control system from HoneyWell
  • Electronic self-diagnostic system with display of error codes on the LCD display
  • Application in systems with separate smoke extraction
  • Possibility of connecting boilers in a cascade

Benefits of switching to HoneyWell's Aurora system:

  • Modern inverted display;
  • Lack of manual adjustment of the gas valve, the possibility of adjustment from the control panel;
  • Adjustable display backlight;
  • The possibility of introducing a system without a pressure switch, control by ionization current and temperature;
  • The impossibility of "sticking" buttons, specially designed ergonomics;
  • Special "demo" operating mode of the board for outlets;
  • Two levels of boiler control parameters (40 parameters are available for fine tuning the boiler for a specific heating system);
  • A proven solution from a global manufacturer.

Reliability:

  • Electronic system of self-diagnostics with an output of codes of errors on ZhK the display.
  • Stable operation at low pressures water, coolant, gas and voltage drops.
  • Stainless steel pipes with 5 times longer service life than copper pipes.
  • All manufactured boilers are tested on test benches, test engineers are personally responsible for each product.

Safety:

  • Stopping the gas supply to the boiler when:
    • extinction of the burner flame;
    • overheating of the coolant;
    • violation of smoke removal;
    • interruption of power supply;
    • coolant pressure drop below the maximum allowable values.
  • discharge of the coolant at a pressure in the heating system above 0.3 MPa (3 bar).
  • Built-in anti-freeze function.
  • Built-in automatic pump blocking protection.
  • The function of checking the freezing of the heat exchanger when starting the boiler.
Design:
  • The use of a system of two heat exchangers - copper for the heating circuit and steel for the DHW circuit significantly reduces the formation of scale and the cost of service.
  • Expansion tank located inside the chamber with access from the front, the nipple for controlling the air pressure in the tank is located on the top wall of the boiler for ease of maintenance.
  • Burner with rear manifold for easy maintenance (cleaning) of the burner.
  • The front and side walls are glued with 10 mm thick insulation, which significantly reduces the noise level of the operating boiler and the temperature of the external panels of the boiler.
  • The sealed chamber is integrated with the front cover and side walls, which lightens the weight of the boiler and simplifies maintenance.
  • The electronic board is located in plastic panel with easily removable back cover for easy access to the board. The electronic board is protected against splashes and jets of water according to IPX5D
  • To access the components of the hydraulic group, the control panel is easily folded down.
  • A new system of protection against the formation of condensate in the pressure switch and pressure switch tubes has been introduced:
    • at the place where the tubes are connected to the fan, a special baffle is installed that protects against exposure to cold air;
    • a nipple with a 1 mm hole is installed on the tube near the pressure switch for sucking air from the chamber and removing it into the fan along with condensate;
    • the pressure switch is located in the corner of the combustion chamber and is as far away from exposure to cold air as possible;
    • the pressure switch is located horizontally in such a way that a slope is formed towards the fan to drain condensate;
    • short tube length.​

Wall-mounted gas double-circuit boiler BaltGaz Neva 24 Turbo with closed combustion chamber.
The country of origin is the Russian Federation.
Trademark Neva BaltGaz group of companies
Detailed information about BaltGaz.
Appearance
New modern cladding and control panel design.
Removable front cover with two screws for easy repair and maintenance.
Hinged side walls for ease of repair and maintenance.
Informative display with blue backlight.
The control panel buttons are made of silicone.
The manometer is located at the bottom of the boiler.
Comfort in use
Display of water temperature on the liquid crystal display.
Automatic maintenance of the set temperature with an accuracy of 1°C.
Options and accessories:
connection of a wired control panel;
connection of a room thermostat;
connection of the outdoor temperature sensor;
connection GSM module for remote control and remote monitoring of the operation of the boiler through SMS commands;
channel separator for the use of a boiler with a separate chimney;
Reliability
Electronic system of self-diagnostics with an output of codes of errors on ZhK the display.
Stable operation at low pressures of water (from 0.015 MPa), gas (from 0.6 kPa) and voltage drops (from 185 to 250 V).
Stainless steel pipes with 5 times longer service life than copper pipes.
Service life 12 years.
All manufactured boilers are tested on test benches, test engineers are personally responsible for each product.
Safety
Stopping the gas supply in the boiler when:
extinction of the burner flame;
heating of the coolant above 95°С;
violation of smoke removal;
interruption of power supply;
coolant pressure drops below the maximum allowable values;
Discharge of the coolant at a pressure in the heating system above 0.3 MPa (3 bar)
Built-in anti-freeze function
Built-in automatic pump blocking protection.
The function of checking the freezing of the coolant when starting the boiler
Design
Convenient access to the expansion tank when servicing the boiler. The nipple for air pressure control in the tank is located on the upper wall of the boiler, access to the nipple is carried out without dismantling the boiler.
The front and side walls are glued with thermal insulation, which significantly reduces the noise level of the operating boiler and the temperature of the external panels of the boiler.
The electronic board is located in a plastic case with an easily removable rear cover for easy access to the board. The electronic board is protected against splashes and jets of water according to IPX5D.
To access the components of the hydraulic group, the control panel is easily folded down.
A new system of protection against the formation of condensate in the pressure switch and pressure switch tubes has been introduced:
a special deflector is installed at the connection point of the tubes to the fan, designed to protect the connection point of the pressure switch tubes from cold air;
a special sleeve with a hole for removing condensate from the tube with combustion products is installed in the tube at the pressure switch;
the pressure switch, due to its location, is maximally protected from exposure to cold air;
pressure switch tubes are located with a slope towards the fan to drain condensate;
the short length of the tubes reduces the amount of condensate formed;
Heat exchanger (Italy)
Bithermic six-pipe heat exchanger manufactured using the most advanced technology.
The width of the combustion chamber is 225 mm.
The heat exchanger is coated with an aluminum silicate compound for additional protection from external influences.
Burner (Italy)
Atmospheric 11-section burner of the latest generation.
Low level of harmful emissions and low level noise.
Cleaning of a torch is made without dismantling of gas communications.
The material of the burner sections is high-quality aluminized steel.
Hydrogroup (Italy)
The hydraulic group is being tested in Italy and additionally as part of the product at the BaltGaz Group plant.
The hydraulic group is equipped check valve to protect against leakage of the coolant from the heating circuit when the make-up tap is not closed and the water pressure in the DHW circuit is low.
The hydrogroup includes:
circulation WILO pump(Italy);
automatic air vent;
safety valve 3 bar;
pressure sensor in the heating circuit at 0.6 bar;
automatic bypass valve;
DHW flow sensor;
DHW flow limiter at 10 l/min;
heating circuit make-up tap with check valve;
valve for draining the coolant from heating;
Electronic board (Italy)
Built-in ignition transformer on the board.
The wiring of the board and the boiler is divided into two parts: high and low voltage to improve the stability of the electronic board.
Reliable 10A fan and pump relays.
A spare fuse is included under the cover of the control box.
The connector for connecting the remote control and the room thermostat is placed outside the panel housing for easy connection.
Fan (Italy)
Reliable Italian manufacturer, market leader in Europe.
Cast aluminum body.
Gas supply regulator (Japan)
Reliable manufacturer, one of the leaders in the production of gas valves in the world.
The connection of the gas line at the inlet and outlet is 3/4 inch, which ensures stable boiler power when the gas pressure drops.
Very reliable gas valve: more than 90% of gas valve failures are due to improper adjustment (use of a magnetic screwdriver).
Expansion tank (Italy)
The volume of the tank is 6 liters, which allows you to connect the boiler to a heating system up to 70 liters without an additional expansion tank.

Communications to which the boiler is connected

Boiler piping diagram


All accessories imported (Italy, Holland) are available.
This equipment allows you to reduce gas consumption by 15-25%.
Our experts will advise you on all issues, help you choose the equipment. Contact.

Video presentation of the Baltgaz Turbo boiler

Gas wall-mounted boiler BaltGaz NEVA Turbo is a new generation device. Thanks to the use of a special coating on the internal surfaces of the casing, the noise level of the boiler during operation is minimized.

BaltGaz NEVA Turbo are economy-class double-circuit wall-mounted gas boilers with a separate heat exchanger and forced exhaust of combustion products. High efficiency for boilers of this class corresponds to the level of three stars according to the European classification. The new system of protection against the formation of condensate in the pressure switch and the pressure switch tubes increases the service life and comfort of operation. Easily removable front cover with two screws and folding side walls make maintenance as convenient as possible.

Advantages of the gas wall-mounted boiler BaltGaz NEVA Turbo

  • Double-circuit gas boiler
  • Copper heat exchanger of our own production for the heating circuit
  • Steel plate heat exchanger for hot water circuit
  • Only European reliable components
  • AURORA control system from HoneyWell
  • Electronic self-diagnostic system with display of error codes on the LCD display
  • Application in systems with separate smoke extraction
  • Possibility of connecting boilers in a cascade

Benefits of switching to HoneyWell's Aurora system:

  • Modern inverted display;
  • Lack of manual adjustment of the gas valve, the possibility of adjustment from the control panel;
  • Adjustable display backlight;
  • The possibility of introducing a system without a pressure switch, control by ionization current and temperature;
  • The impossibility of "sticking" buttons, specially designed ergonomics;
  • Special "demo" operating mode of the board for outlets;
  • Two levels of boiler control parameters (40 parameters are available for fine tuning the boiler for a specific heating system);
  • A proven solution from a global manufacturer.

Reliability:

  • Electronic system of self-diagnostics with an output of codes of errors on ZhK the display.
  • Stable operation at low pressures of water, coolant, gas and voltage drops.
  • Stainless steel pipes with 5 times longer service life than copper pipes.
  • All manufactured boilers are tested on test benches, test engineers are personally responsible for each product.

Safety:

  • Stopping the gas supply to the boiler when:
    • extinction of the burner flame;
    • overheating of the coolant;
    • violation of smoke removal;
    • interruption of power supply;
    • coolant pressure drop below the maximum allowable values.
  • discharge of the coolant at a pressure in the heating system above 0.3 MPa (3 bar).
  • Built-in anti-freeze function.
  • Built-in automatic pump blocking protection.
  • The function of checking the freezing of the heat exchanger when starting the boiler.
Design:
  • The use of a system of two heat exchangers - copper for the heating circuit and steel for the DHW circuit significantly reduces the formation of scale and the cost of service.
  • The expansion tank is located inside the chamber with access from the front, the nipple for controlling the air pressure in the tank is located on the top wall of the boiler for ease of maintenance.
  • Burner with rear manifold for easy maintenance (cleaning) of the burner.
  • The front and side walls are glued with 10 mm thick insulation, which significantly reduces the noise level of the operating boiler and the temperature of the external panels of the boiler.
  • The sealed chamber is integrated with the front cover and side walls, which lightens the weight of the boiler and simplifies maintenance.
  • The electronic board is located in a plastic panel with an easily removable rear cover for easy access to the board. The electronic board is protected against splashes and jets of water according to IPX5D
  • To access the components of the hydraulic group, the control panel is easily folded down.
  • A new system of protection against the formation of condensate in the pressure switch and pressure switch tubes has been introduced:
    • at the place where the tubes are connected to the fan, a special baffle is installed that protects against exposure to cold air;
    • a nipple with a 1 mm hole is installed on the tube near the pressure switch for sucking air from the chamber and removing it into the fan along with condensate;
    • the pressure switch is located in the corner of the combustion chamber and is as far away from exposure to cold air as possible;
    • the pressure switch is located horizontally in such a way that a slope is formed towards the fan to drain condensate;
    • short tube length.​