Installation and principle of operation of the control panel S2000M. Security and fire control panel S2000M S2000m latest version





Description Car S2000-M

Car S2000-M is a security and fire control panel designed for use as part of a security and fire alarm together with the signal-20, signal-20P, S2000-4, signal-20 series 02 control panels, S2000-KDL two-wire line controllers, S2000 fire control and control devices -ASPT", "S2000-SP1" and "S2000-KPB" relay blocks, "S2000-K" and "S2000-KS" keyboards, "S2000-BI" display units, "S2000-2" access control controllers.

It is the development of the remote control, while maintaining its functions and at the same time having new features.

Additional features:

  • New case with a large liquid crystal display with more information (2 lines of 16 characters). There are functional LED indicators "ALARM", "FIRE", "FAULT", "TROUBLE", displaying the state of the object
  • The number of partitions and alarm loops that can be included in these partitions has increased, which allows you to use this remote control on larger objects
  • Increased the maximum number of user passwords
  • Sections can be combined into groups. This simplifies the group control of arming and disarming. Any section can be included in several groups
  • Possibility to set text names not only for partitions and users, but also for groups of partitions and alarm loops. Text title can be up to 16 characters long
  • Ability to change the names of messages from signaling loops. For each alarm loop added to the console database, 32 custom renaming scripts can be set. Each scenario allows you to set new text names and display type for any 4 standard messages on the device alarm loop
  • The remote control is configured by the "Database Administrator" program from the "Orion Pro" workstation or by the "pprog.exe" utility version 2.00 and higher

Specifications Bolide S2000-M

  • Unit: 1 piece
  • Dimensions (mm): 140x114x25
  • Weight (kg): 0.30
  • The number of devices connected to the RS-485 output - up to 127
  • Number of partitions - up to 511
  • Number of partition groups - up to 128
  • The number of alarm loops that can be combined into sections - up to 2048
  • Number of user passwords up to 2047
  • Number of automatically controlled relay outputs up to 256
  • Number of "entrance zones" - up to 32
  • The volume of the ring buffer of events - up to 1023 messages
  • RS-485 interface line length up to 3000 m
  • The length of the RS-232 interface line for communication with the printer is up to 20 m
  • Power supply - from a redundant DC source (for example, "RIP-12" or "RIP-24"). Supply voltage range - from 10.2 to 28.4 V.
  • Typical current consumption - 70 mA at 12 V supply voltage or 35 mA at 24 V supply voltage
  • Working temperature range - from 0 to +40 °C
  • Weight - no more than 0.3 kg
  • Overall dimensions - 140x114x25 mm

Purpose:
is intended for information integration of Orion ISO devices in order to organize a single control center and collect system messages, combine alarm loops into sections, create cross-links between sections and outputs of different devices, expand the possibilities of displaying information.
The interaction between the "S2000M" console and the ISO "Orion" devices takes place via the RS-485 interface with the transfer of information in the "Orion" protocol.

Main characteristics:
Provides display of system messages on a symbolic liquid crystal screen and their saving in a non-volatile buffer (archive) with the possibility of viewing. Controls the display of partition states on the S2000-BI, S2000-BKI and S2000-BI display units. 01. For better perception of messages, it is possible to set text descriptions of sections, alarm loops, addressable detectors and users.
Allows you to manage partitions (arm and disarm) using a PIN code on the remote control itself or on the S2000-K and S2000-KS keypads, Touch Memory keys or Proximity cards from any device that has an input for connecting a reader , from blocks "S2000-BKI", SMS messages through "UO-4S".
Allows you to remotely control the S2000-ASPT and Potok-3N devices with commands from the remote control and from the S2000-PT display units: select automatic or manual control mode for fire extinguishing installations, initiate their start-up and start-up cancellation. Controls the display of the states of the fire extinguishing zones on the "S2000-PT" and the states of the water fire extinguishing installation on the "S2000-BI" version. 01.
Provides differentiation of user access rights to management functions.
It has the function of automatic control of the outputs of control panels, starting and relay blocks according to 45 different programs.
Supports scenarios for controlling outputs, voice announcements, alarm loops and access modes. Output control scenarios allow you to create your own control programs for executive devices. Voice notification control scenarios allow you to control the Rupor series voice notification devices and can be used to announce synchronously and with the division of an object into zones. Access mode control scenarios are designed to automatically open doors on escape routes in case of fire. Loop control scenarios can be used to automatically control alarm loops (for arming or disarming) or operating modes of S2000-ASPT and Potok-3N devices based on system events.
Supports connection to Orion workstation or Orion Pro workstation to increase functionality and expand the system.
It has the ability to connect a printer with a serial RS-232 interface for documenting events or a PC with software AWS "S2000" for displaying events, states of sections and alarm loops.
Ensures the transmission of notifications by the S2000-IT, UO-4S, UO-Orion and S2000-PP devices. It has the ability to connect the ATS100 radio transmitter of the LARS security radio system or the RS-202TD radio transmitter of the Reef String 202 security radio system (LONTA 202) to transmit notifications over the radio channel.
Configuring the remote control in the program "Pprog.exe" or in the program module Database Administrator of AWS "Orion Pro".

Buy the C2000M car from Layta at an attractive price. Car S2000M: description, specifications, customer reviews, photos and related products..

The S2000M remote control is designed to monitor the status of devices, and to collect information from security system devices, alarm indication, fire alarms and automation control. It connects all the necessary devices into an integral system for their effective interaction.

What is the control panel S2000M

Such a remote control belongs to the functional subsystem of the Orion security. It can be set so that it unites all devices and provides maximum adaptability. The S2000M remote control is a security remote control, only more unified. It combines ease of use and efficient operation of all devices that are connected.

Such a remote control can serve more than a hundred devices at the same time, not only receiving data and sending signals of various commands, but also feeding them with electricity. The voltage that will allow you to work for normal operation is from 10.2 to 28.4 V. The current strength will depend on the operating mode.

The control panel S2000M received modern design which allows you to use it as conveniently and efficiently as possible. It has hinged control, a keypad and a two-line LCD display, which allows you to control the entire system as simply as possible. The body size is very compact - 140 x114x25 millimeters, and the weight is 300 grams. Also, such a device allows you to control the system remotely, using radio frequency communication channels.

Principle of operation

This console unites all connected devices into one system, which is very easy to manage. If a malfunction, fire or accident occurs, the LCD screen will display a problem alert. Also, it allows you to manage partitions, arm or disarm them.

Application area

The S2000M control panel is used:

  1. For informational unification of all devices in order to create a single control center.
  2. To receive system messages from instruments.
  3. In order to combine alarm loops into sections.
  4. In order to create connections between these compartments and the outputs of various devices.
  5. Display information received by connected devices.
  6. For remote control devices and monitoring their condition.
  7. Alarm settings.
  8. Removal from the alarm.
  9. To collect information from devices.

The control panel can be used in any premises: shops, hospitals, offices, private houses, apartments, entertainment centers, restaurants. Where there may be a need to monitor the condition of the premises.

Specifications:

  • The number of devices connected to the RS-485 output is up to 127.
  • The number of sections is more than five hundred.
  • The number of section groups is more than one hundred and twenty.
  • The number of alarm loops that can be combined into sections is more than two thousand.
  • Number of user passwords up to 1023.
  • The number of relay outputs controlled in automatic mode is up to 256.
  • Number of entry zones up to 32.
  • The number of users is more than two thousand.
  • The volume of the ring buffer of events is up to 1023 messages.
  • The length of the RS-485 interface line is four kilometers.
  • The length of the RS-232 interface line for communication with the printer is twenty meters.
  • Power supply - from a redundant DC source. Voltage range from 10.2 to 28.4 V.
  • Typical current consumption is 70 mA at 12 V supply voltage or 35 mA at 24 V supply voltage.
  • The temperature at which the remote control operates is from 0 to +40 °C.
  • Weight does not exceed 300 grams.
  • The dimensions of the remote control are 140x114x25 millimeters.


Purchase

You can buy the S2000M control and management console in stores in any city or you can order it using online stores. With the help of an online store, this is much easier to do, because time is spent much less than when you need to drive around the city and look for what you need. On the sites you can see all the characteristics of interest and compare prices, you can also get qualified help when choosing or installing a remote control.

How much is

The price of such a device varies from 6370 rubles to 6700 rubles, it all depends on the store and the quality of the device itself. If you buy in bulk, then the price of one remote control will be several hundred less, and if you order a large number of goods, then the price for one will be much less.

Installation and setup

The installation of the S2000M control panel itself is simple. There is a very simple combination, which will help you take the loop, and requires you to enter the number of the controller and the loop - this is the password 1-2-3-4. In order to take or remove the created partitions, you need to enter 1-1-1-1, but this combination is non-standard, it is set during the programming of the remote control.

Setting up and installing the remote control is very simple, because the device itself was developed for professional and for ordinary household use. Along with the remote control comes the instruction itself, which is written in an understandable language and will be easy to understand even for a non-professional. Also, this device has a reprogramming function, which is also carried out without any problems.

Setting up the remote control is very simple:

  1. In order to arm you need to enter the password (1111), after dialing the partition number (1-10) press ENTER – 1…10:disarm – ENTER – arm – ENTER – arm 1…10 – CLR if the clock indication appears, then everything is set correctly.
  2. In order to disarm the device, you need to enter the password (1111), after dialing the partition number (1-10), press ENTER - 1 ... 10: take - ENTER - disarm - ENTER - disarm 1 ... 10 - CLR and again until the clock appears .
  3. If you need to reset the alarm, then press fire, then the section number (1-10) CLR until the clock appears, then dial the password (1111), then the number of the section where the fire was (1-10) - ENTER - fire - ENTER - remove - ENTER - remove 1 ... 10 - CLR and again until the clock appears.

Additional features:

  1. New case, which is equipped with an LCD indicator.
  2. LED indicators that show the status of a particular object: alarm, fire or accident and malfunction.
  3. A large number of sections and loops.
  4. Different departments can be combined into groups for more convenient management.
  5. Also, you can set text names for groups of sections and loops, and not only for the users themselves.
  6. You can change the names of notifications from alarm loops and set different scenarios.
  7. The database manager program allows you to configure the console.

http://luis.ru - on this site you can find detailed information about the control panel S2000M, as well as place an order.

It is the development of the "S2000" remote control, retaining its functions and at the same time having new features. The device is intended for use as part of a security and fire alarm system together with the Signal-20, Signal-20P, S2000-4, Signal-20 series 02 control panels, S2000-KDL two-wire line controllers ", fire control and control devices "S2000-ASPT", relay blocks "S2000-SP1", and "S2000-KPB", keyboards "S2000-K" and "S2000-KS", display units "S2000-BI" , access control controllers "S2000-2".

Additional features:

  • New case with a large liquid crystal display with more information (2 lines of 16 characters). There are functional LED indicators "ALARM", "FIRE", "FAULT", "TROUBLE", displaying the state of the object;
  • The number of partitions and alarm loops that can be included in these partitions has increased, which allows this remote control to be used on larger objects.
  • Increased the maximum number of user passwords;
  • Sections can be combined into groups. This simplifies the group control of arming and disarming. Any section can be included in several groups;
  • Possibility to set text names not only for partitions and users, but also for groups of partitions and alarm loops. The text title can be up to 16 characters long;
  • Ability to change the names of messages from signaling loops. For each alarm loop added to the console database, 32 custom renaming scripts can be set. Each scenario allows you to set new text names and display type for any 4 standard messages on the instrument's alarm loop;
  • The remote control is configured by the "Database Administrator" program from the "Orion Pro" workstation or by the "pprog.exe" utility version 2.00 and higher.

Specifications

  • The number of devices connected to the RS-485 output - up to 127;
  • Number of sections - up to 511;
  • Number of partition groups - up to 128;
  • The number of alarm loops that can be combined into sections - up to 2048;
  • Number of user passwords up to 1023;
  • Number of relay outputs controlled in automatic mode up to 256;
  • The number of "entrance zones" - up to 32;
  • Number of users - up to 2047;
  • The volume of the ring buffer of events - up to 1023 messages;
  • RS-485 interface line length up to 4000 m;
  • The length of the RS-232 interface line for communication with the printer is up to 20 m;
  • Power supply - from a redundant DC source (for example, "RIP-12" or "RIP-24");
  • Supply voltage range - from 10.2 to 28.4 V;
  • Typical current consumption - 70 mA at a supply voltage of 12 V or 35 mA at a supply voltage of 24 V;
  • Working temperature range - from 0 to +40 °C;
  • Weight - no more than 0.3 kg;
  • Overall dimensions - 140x114x25 mm.

S2000M Remote control and management of security and fire. Designed to work as part of the address system security and fire alarm and management of fire fighting equipment. Together with ISO "Orion" devices, it can perform the functions of a block-modular device for receiving and controlling security and fire, a control device for light, sound and voice warning, gas, powder aerosol and water fire extinguishing, smoke protection, engineering systems. Information interaction of blocks is carried out via a wired communication line RS-485

  • Indication of the modes "Alarm", "Fire", "Start", "Stop", "Fault", "Disabled". The ability to view individual zones (sections) and system elements that have these states, with display on a symbolic indicator. Sound signaling of alarms, fires, starts and malfunctions on the built-in sound signaling device. Indication of the status of security zones, fire fighting equipment and other actuators on the blocks "S2000-BI", "S2000-BKI", "S2000-PT", "Potok-BKI"
  • Automatic control of means of light and sound notification, smoke protection, engineering equipment, signal transmission outputs "Alarm", "Fire", "Start" and "Fault" using control-start and signal-start blocks, receiving-control blocks. Automatic start and stop of devices of the voice notification of the Rupor series. Automatic control of operating modes of the access control and management subsystem to unblock escape routes in case of fire.
  • Manual control from the keyboard of the remote control and display units:
    • management of security and fire alarm modes: arming, disarming, resetting alarms, disabling detectors and actuators (only those controlled by the remote control);
    • manual start and stop of light, sound and voice warning, smoke protection, engineering equipment;
    • control of "S2000-ASPT" devices using "S2000-PT" blocks: manual start and stop of the fire extinguishing installation, suspension of the start delay and immediate start without delay, selection of automatic or manual control mode of the fire extinguishing installation, alarm reset;
    • control of Potok-3N devices using Potok-BKI blocks: manual start and stop of the fire extinguishing installation, selection of automatic or manual control mode of the installation
  • Possibility of connection to AWP "Orion Pro" to expand the possibilities of monitoring the state of the protected object and control
  • Possibility of transmitting notices to the security console using communication blocks "S2000-IT", "UO-4S", "S2000-PGE" and "S2000-PP". Possibility to connect the ATS100 radio transmitter of the LARS radio security system, RS-202TD of the "Reef String 202" ("LONTA 202") or TRX-150 radio security system for transmitting notifications via radio channel
  • Event log with the ability to view it on the remote control screen and print on a printer with a serial RS-232 interface
  • Configuring the remote control in the program "Pprog.exe"
PARAMETER NAME PARAMETER VALUE
Number of devices and devices ISO "Orion" connected to the RS-485 line, not more than 127
RS-485 interface 1
Communication line length RS-485, no more 3000 m
RS-232 interface 1
Number of devices connected to the RS-232 output 1
(computer with workstation, printer, ATS100 or TRX-150 radio transmitter (via converter) or RS-202TD radio transmitter)
Communication line length RS-232, no more 20 m
Number of alarm loops and addressable detectors grouped into sections, no more than 2048
Number of relay outputs controlled in automatic mode, no more 256
Number of sections, no more 511
Number of partition groups, no more 128
Number of user passwords, no more 2047
Event log size 8000
Liquid crystal display 2 lines x 16 characters, backlit
Nutrition from a redundant DC source
Supply voltage 10.2 to 28.4 V
Average current consumption in standby mode at supply voltage 12 V 60 mA
at 24 V supply voltage 35 mA
Maximum current consumption in alarm mode at supply voltage 12 V 120 mA
at 24 V supply voltage 65 mA
Working temperature range from minus 10 to +55 °C
Degree of protection of the shell IP30 (when wall mounted)
Weight, no more 0.3 kg
dimensions 140x114x25 mm
Type of connection to the device terminal block for screw, wire from 0.2 to 1.5 sq. mm